Thick Film

Thick Film Division

ISO 9001 CERTIFIED
MSIRP™, MINI-SYSTEMS, INC. RELIABILITY PROGRAM

The reliability program will provide customers with real-time data on similar products. These products are tested on a continuous basis and the data will accompany the certificate of conformance. The data is selected from Mini-Systems in-house QPL testing. This data will be displayed in a graphical representation and plotted against military standard criteria. Samples are selected in accordance with MIL-PRF-55342.

SAMPLE SELECTION

  • SAMPLES / DATA ARE SELECTED FROM THE CONTINUOUS QPL TESTING
  • SAMPLES WILL MEET THE REQUIREMENTS OF MIL-PRF-55342
  • DATA IS ALSO TAKEN FROM PARTS THAT ARE CURRENTLY BEING TESTED AND MEET THE PREVIOUS REQUIREMENTS

APPLICABLE MILITARY STANDARDS

  • MIL-PRF-55342, CHARACTERISTIC “K”
  • MIL-STD-202
  • MIL-STD-883

TESTS PERFORMED

  • LIFE TEST
    • MIL-PRF-55342, CHARACTERISTIC “K”
    • FAILURE RATE S
    • 2000 HOURS (+72/-24), 70°C (±5°C), 250mW
    • ΔR REQUIREMENT ±0.50%
    • STYLES RM1005 (100mW) & 1206 (250mW)
  • HIGH TEMPERATURE EXPOSURE TEST
    • MIL-PRF-55342, CHARACTERISTIC “K”
    • 100 HOURS (±4) AT 150°C (±5°C)
    • ΔR REQUIREMENT ±0.50%
  • THERMAL SHOCK TEST
    • MIL-PRF-55342, CHARACTERISTIC “K”
    • 5 CYCLES, -65°C (+0/-10) TO 150°C (+10/-0)
    • ΔR REQUIREMENT ±0.50%

DATA

  • DATA WILL BE SUPPLIED WITH CERTIFICATE OF CONFORMANCE ON HIGH RELIABILITY ORDERS THAT DO NOT REQUIRE TESTING

FOR MORE INFORMATION CONTACT MSI QUALITY ASSURANCE DEPARTMENT

Mini-Systems, Inc. Thick Film Division
20 David Road, P.O. Box 69, North Attleboro MA 02761-0069
Phone: (508) 695-0203 Fax: (508) 695-6076

 Life-Test-Data_Thick

 

Thick Film Catalog(.pdf)

 

Contact Information

Quality Assurance: Felix Santilli – mail

 Sales Contact: Christine Caponigro (508) 695- 0203 – Fax: (508) 695-6076 – mail